|
Volume 66, Number 5-6, 2021
Theoretical, Mathematical, and Computational Physics
Geodesics on the Extended Siegel–Jacobi Upper Half-Plane Stefan Berceanu Romanian Journal of Physics 66,
107 (2021)
The semidirect product of the real Heisenberg group ${\rm H}_1(\mathbb {R})$ with ${\rm SL}(2,\mathbb {R})$, called the real Jacobi group $G^J_1(\mathbb {R})$, admits a four-parameter invariant metric expressed in the S-coordinates. We determine the geodesic equations on the extended Siegel--Jacobi upper half-plane $\tilde {\mathcal {X}}^J_1=\frac {G^J_1(\mathbb{R} )}{\rm {SO}(2)}\approx \mathcal {X}^J_1\times \mathbb {R}\approx \mathcal {X}_1\times \mathbb {R}^3$, where $\mathcal {X}^J_1$ ($\mathcal {X}_1)$ denotes the Siegel-Jacobi upper half-plane (respectively Siegel upper half-plane). Equating successively with zero the values of the three parameters in the geodesic equations on $\tilde {\mathcal {X}}^J_1$, we get the geodesic equations on $\mathcal {X}^J_1$, $\mathcal {X}_1$ and ${\rm H}_1(\mathbb {R})$.
Numerical Solution to Nonlinear Transient Coupled-PDE by the Modified Multiquadric Meshfree Method S. Kaennakham, K. Chanthawara Romanian Journal of Physics 66,
108 (2021)
The conventional global Multiquadric Radial Basis Function (MQ-RBF) collocation meshfree method is modified using the Green second identity. This work proposes the numerical application of this modified method in solving a transient, nonlinear and coupled-PDE called Burgers’ equations in two dimensions. Its computational implementation to the PDE is detailed and two benchmarking examples are demonstrated. Solutions obtained are validated against both those documented in literature and their exact forms. It is found in this investigation that with suitable MQ shape parameters, good agreements in solutions’ quality can successfully be achieved.
Conformal Vector Fields and Dynamics of Kantowski Sachs and Bianchi Type III Perfect Fluid Space-Times in f(R,T) Gravity Ghulam Shabbir, M. Jamil Khan, Fiaz Hussain, Muhammad Ramzan,
Ashfaque H. Bokhari Romanian Journal of Physics 66,
109 (2021)
The aim of this paper is to investigate proper conformal vector fields (CVFs) and dynamics of Kantowski Sachs (KS) and Bianchi type (BT) III perfect fluid space-times in the f(R,T) gravity. Initially, we have found some solutions in f(R,T) gravity by writing it as a sum of f(R) and the trace of matter. Implementing a classification scheme, we found that the solutions fall in seven different cases. Inspecting all cases separately, we reach at the fact that there exists only one case in which the space-time admit proper CVF. In rest of the six cases, the CVFs become the Killing vector fields (KVFs). We have also calculated some dynamical parameters corresponding to each of the obtained solution.
Auto- and Hetero-Baecklund Transformations for a Generalized Three-Coupled Korteweg-de Vries System Xin-Yi Gao, Yong-Jiang Guo, Wen-Rui Shan Romanian Journal of Physics 66,
110 (2021)
In this paper, for a generalized three-coupled Korteweg-de Vries system, a symbolic computation method leads to two auto-Bäcklund transformations with the associated soliton solutions, and a hetero-Bäcklund transformation. The obtained results depend on the coefficients in the system.
Convective Flow of Nanofluid Round Plumes in the Presence of Magnetic Field Cristian V. Vraciu, Rares Iovanescu Romanian Journal of Physics 66,
111 (2021)
In the present work we formulate a theoretical model of round nanofluid plumes in the presence of magnetic field. We consider both the entrainment hypothesis and the Priestley-Ball formulation in order to obtain a closed system of ordinary differential equations. Once solved, the obtained system of equations predict the heat and mass transfer of the convective plume. Solving numerically the system of equations, we analyze the effect of the applied magnetic field on the vertical velocity of the nanofluid plume. We show that the magnetic field inhibits the convective flow. Thus, our formulation can be used to study the effect of the magnetic field in applications where the convective heat transfer need to be externally controlled.
Nuclear Physics
Investigations on the Properties of the OSL Dosimetry System from ELI-NP at Gamma Rays D. Aranghel Romanian Journal of Physics 66,
307 (2021)
Optically Stimulated Luminescence (OSL) signals of the BeOSL dosimetry system from IFIN-HH, the Extreme Light Infrastructure Nuclear Physics (ELI-NP) were checked at gamma radiations for the personal dose equivalent Hp(10). Irradiations were performed at the Secondary Standards Dosimetry Laboratory, the Ionizing Radiation Metrology Laboratory, Romania from IFIN-HH. Coefficient of variation, non- linearity, fading and response to natural radiation have been tested. Dose response was found to be linear and a minimum detectable dose of ~ 20 μSv was found. It was shown, that the BeOSL dosimetry system out of our laboratory for use in all applications in whole-body dosimetry measuring photons is suitable.
Condensed and Soft Matter Physics
Electrical Devices Based on Hybrid Magnetorheological Suspensions: Realization, Phenomenological Modeling and Technical Characteristics Maria Bălăşoiu, Mădălin Bunoiu, Larisa Marina Elisabeth Chirigiu, Ioan Bica Romanian Journal of Physics 66,
604 (2021)
The paper presents the production of electrical devices (EDs), using hybrid magnetorheological suspensions (hMRSs) composed of silicone oil, carbonyl ironmicroparticles (20% and 40% vol. conc.) and cotton fabric. Two EDs devices are made of hMRSs, with the dimensions 30 × 30 × 2 mm3. Using the setup described in the paper, the equivalent electrical capacity and electrical resistance of the EDs as a function of time are measured for fixed values of magnetic flux density. It is shown that the measured values are significantly influenced by the magnetic field and are stable over time. The mechanisms involved in the observed effects are described in the dipole approximation model. Together with these mechanisms, the main technical characteristics of the obtained EDs were developed and determined, namely, the nominal values of the equivalent electrical capacitance and resistance and the relative deviations from these values, the magnetocapacitive and magnetoresistive effects of the EDs. The obtained results can open research directions for the realization of magnetic field sensors, sensors, and transducers of deformations and mechanical tensions, protection equipment against electromagnetic smog, etc.

Numerical Analysis of a Multilayer Containing Metal Nanoparticles for Photonic Integrated Circuits Applications Muin F. Ubeid, Mohammed M. Shabat Romanian Journal of Physics 66,
605 (2021)
In this work, the optical properties of a layered structure containing iron nanoparticles are analyzed. Expressions for the electric and magnetic fields in each layer are provided using Maxwell's equations. The reflectance and transmittance of the structure are given in terms of Fresnel coefficients. Computations for the overall reflection and transmission are illustrated in terms of angle of incidence, wavelength, and layer thickness when the filling factor changes. The theoretical and numerical results obtained in this work provide some insight into the design of optical integrated circuits.
The Effects of Triple-Layer Antireflection Coating on Current Density of Solar Cell Mohammed M. Shabat, Sahar M. Abuibaid, Hana M. Mousa Romanian Journal of Physics 66,
606 (2021)
We study the electromagnetic wave propagation through a triple layer antireflection coating sandwiched between glass cover and silicon substrate. A theoretical and numerical discussion of maximum short-current density for both TE and TM polarizations show that the triple-layer antireflection coating reduces losses and increases the current generation leading to an increase in the efficiency of the solar cell.
Finite Element Analysis of Multilayered ZnO/AIN/Si Structure Saw Sensor for Efficient VOCS Gas Detection M. Moustafa, T. Alzoubi, M. Elnaggar, G. Laouini Romanian Journal of Physics 66,
607 (2021)
Surface Acoustic Wave (SAW) gas sensor device based on the ZnO/AIN/Si structure is numerically studied using the Finite Element Method (FEM) simulations employed by the Comsol Multiphysics package. The analyses of the device performance concerning the phase velocities and electromechanical coupling factor, K2, are carried out and discussed for both Rayleigh and Sezawa wave modes. The structure is initiated by studying the ZnO/Si model, and the obtained results are validated by comparison to previously reported experimental results that match our numerical simulations. To enhance the performance of the SAW device, an AlN layer is inserted between ZnO and Si layers. The influence of ZnO and AIN layer thickness of the two SAW modes is analyzed. The obtained results reveal that, for Sezawa mode, high velocities of up to 5800 m/s is achieved through optimizing the thickness ratio of AlN/ZnO. The sensor sensitivity to gas concentration in the air is examined for seven Volatile Organic Compounds (VOCs) using a thin Polyisobutylene (PIB) layer for sensor demonstration. The results show a linear dependence of the sensitivity over the investigated gas concentrations. The study shows a remarkable sensitivity improvement of the SAW sensor achieved by the Sezawa wave mode compared to the Rayleigh one. For instance, a sensor sensitivity of 1.097 Hz/ppm for Sezawa mode is compared to 0.692 Hz/ppm for Rayleigh mode for the standard Dichloromethane gas (DCM).
Biophysics and Medical Physics
Characterization of Dental Materials by Compton-to-Rayleigh Scattering Ratio Measured with Hand-Held XRF Spectrometers Eugen A. Preoteasa, Daniela Cristea-Stan, Adela C. Scafes, Alexandru Iliescu, Elena S. Preoteasa, Ioana Suciu, Mihaela Chirila, Dan Straja Romanian Journal of Physics 66,
705 (2021)
Fourteen composites for restorative dentistry and other dental materials have been examined by XRF using portable spectrometers. For the first time, the Compton-to-Rayleigh (C/R) scattering ratio was measured from the XRF spectra in view of characterizing dental materials. We took advantage of the fact that the Compton (incoherent) scattering is enhanced by light elements, while the Rayleigh-Thomson (coherent) scattering is favored by heavy elements. The examined biomaterials were very diverse, and the C/R ratio varied from ~0.5 for an endodontic sealer containing a heavy metal to ~8.0 in a purely organic acrylate resin. As dental materials contain both light and heavy elements, the C/R ratio provided synthetic information and could not be used as an analytical parameter. However, the C/R ratio appears as an intrinsic and specific amount, of great potential for the dental materials. In general, materials with different compositions could exhibit similar or close C/R ratio values, and materials with the same qualitative composition but with different concentrations evidenced different C/R values. In particular some newer dental composites (Filtek Bulk Fill and Ariston) are characterized by higher C/R ratios as compared to the corresponding older ones (Filtek and Tetric Ceram, respectively). The C/R data suggest higher concentrations of light elements and lower levels of heavy elements in the newer biomaterials. For other (Tetric Evo Ceram Bulk Fill vs. Tetric Ceram) this rule apparently did not check. The results open a new perspective for the characterization of dental materials by use of the C/R ratio. They inspire the development of a new XRF technique for dental research and point to the need of additional investigations.

Structural Investigation of the Human Teeth Degraded by Acetic Acid M. Todica, M. Muresan-Pop Romanian Journal of Physics 66,
706 (2021)
The degradation of the enamel and dentine of human teeth exposed to the action of acetic acid during different time intervals, as well as the possible recovery of the protective external layers of teeth was analyzed by X-ray diffraction and infrared spectroscopy. The crystalline structure of the teeth, determined mainly by the hydroxyapatite, is strongly affected by the action of the acetic acid. The dentine is more susceptible to degradation compared to enamel. A comparative investigation between behavior of canine and molar showed more resistance of the canine against the acid, and the dentine facet is more susceptible to the degradation. The slow process of grooving of the hydroxyapatite on the surface of the degraded teeth is observed after a long time of immersion in simulated biological fluid and confirmed by the presence of hydroxyl and phosphate functional groups in the FTIR spectra.
Environmental and Earth Physics
Correlations between Macroseismic Intensity Values and Ground Motion Measures of Vrancea (Romania) Subcrustal Earthquakes A. P. Constantin, I. A. Moldovan, R. Partheniu, B. Grecu, C. Ionescu Romanian Journal of Physics 66,
808 (2021)
The correlations between macroseismic intensity (MI) and strong ground motion parameters such as Peak Ground Acceleration (PGA) and Peak Ground Velocity (PGV) for the Vrancea subcrustal earthquakes are compared. The recent Romanian earthquakes, especially Vrancea earthquakes provide valuable data to examine the correlation relationships between these parameters for the entire territory of Romania. The goal of this study is to develop a new empirical relationships between the strong ground-motion records and the observed intensities for major and moderate earthquakes with Mw ≥ 5.4 and epicentral intensity in the range VI to IX MSK degrees that occurred in the period 1977–2009. For each instrumental record we assigned a macroseismic intensity based on the proximity of the site where reported value are available (no more than 3 km distance around the station). The obtained relations between macroseismic intensity and PGA/PGV will be given both as a mathematical equations, but also as corresponding ground motion intervals. The most prominent results available in the literature have shown that macroseismic intensity and ground parameters do not always show a one-to-one correspondence, and the errors associated with the intensity estimation from PGA/PGV are sometimes +/–2 MSK degree. These relations can be used as near realtime response regarding ground shaking severity, and potential damages in the areas affected by the Vrancea earthquakes.

Applied and Interdisciplinary Physics
Composition Studies on "Dumbrăveni" Type Coins – the Case Hoard from Crângul Petreşti Area, Vânători Commune (Vrancea County) D. Cristea-Stan, L. Munteanu, S.-P. Boţan, a.-E. Apostu Romanian Journal of Physics 66,
905 (2021)
The populations that lived on the territory of Dacia, before the Roman conquest, used as a model, for their silver coins, the tetradrachm of the Macedonian king Philip II. A monetary hoard consisting of 91 silver coins imitating these Macedonian issues was discovered in the Crângul Petreşti area, commune of Vânători, Vrancea County with the help of a metal detector by a detectorist, and handed over to the specialists from the Vrancea Museum. The hoard was analyzed with X-Ray Fluorescence method, using a portable spectrometer that allowed us to perform the in-situ (museum) analyzes. From a numismatic point of view, the discovery is particularly important for understanding the Dumbrăveni monetary type, more precisely its first group of issues. From the point of view of the composition of the alloy, coins have a very high title and low concentrations of copper (which was probably added to increase the hardness of the coins) and with traces of lead too. These coins were most likely issued in the series of money that appeared on the territory of Dacia, when there were sufficient resources of silver ore.

PGAA Analyses on Roman Glass Finds from Tomis R. Bugoi, G. Talmaţchi, V. Szilágyi, I. Harsányi, D. Cristea-Stan, S. Boţan, Zs. Kasztovszky Romanian Journal of Physics 66,
906 (2021)
This paper reports the Prompt Gamma Activation Analysis (PGAA) measurements on twenty glass fragments discovered at Tomis, Constanţa, Romania, tentatively dated to the Early Roman period. Most of the analyzed glass samples are colorless, featuring different compositions: antimony decolorized, manganese decolorized or resulting from recycling both types of decolorized glass.
|